Multiport switch block simulink pdf

Zerobased and onebased indexing with the index vector block. Then simulink enters the simulation loop, where each pass through the loop is referred to as a simulation step. To select a case, define the input value using the case conditions parameter. An introduction to using simulink department of engineering. Could any one tell me how can i use a multiport switch in the following example. The switch block passes through the first top input or the third bottom input based on the value of the second middle input. I use a rectangular pulse generator signal on port 1 and a sin wave signal on port 2. In my opinion, the difficulty for users to implement this behavior is inpart due to a problem with word selections. You control the signal flow by setting the switch before you start the simulation or by changing the switch while the simulation is executing. Blocks may have states, which may consist of a discretetime and a continuoustime part. The signal type of the block s output is the same as that of its data inputs.

The value of the control input determines which data input is passed through to the output port. Simulink provides a graphical user interface gui for building models as block diagrams, using clickanddrag mouse operations. An introduction to using simulink university of oxford. Onebased indexing for multiport switch data ports matlab. Zerobased indexing for multiport switch data ports matlab. Combine multiple signals into single signal simulink.

Noncontiguous values for data port indices of multiport. At exactly t 5, the output of the switch block changes from the absolute value to the saturation block. When a block like the switch block or multiport switch block selects among multiple data signals, and any data signal is of an enumerated type, all the data signals must be of that same enumerated type. When i have the sin wave connected, but use the rectangular switch port with a constant, the signal is kind of diagonal instead of a rectangular up and down. Matlab and simulink are registered trademarks of the mathworks, inc. When you find the block you want to use, add it to your model. The manual switch block is a toggle switch that selects one of its two inputs to pass through to the output. The control input of a multiport switch block accepts a realvalued signal of any type except. The value of the control input determines which data input to pass through to the output port. The block output is the element of the input vector whose index matches the control input. Using simulink electrical and computer engineering. The first top input is the control input and the other inputs are data inputs. Blocks in simulink represent different parts of a system.

Select zoom outfrom theview menu or typev to shrink the view. Specify indices is not supported by the multi port switch block parameter data port order for hdl code generation. This example shows how to use a multiport switch block that specifies noncontiguous integer values for data ports. The index vector block is from the simulink signal routing library. A library of basic building blocks implemented in simulink for ternary logic is presented. The block can have two or more output ports and has one input port. The control input of a multiport switch block accepts a. If at least one of the data inputs is a vector, the block output is a vector. When you set data port for default case to last data port, the last data port includes a on the label. You can draw the models as you would with pencil and paper. For example, if the input vector is 18 15 17 10 and the control input is 3, the element that matches the index of 3 zerobased is 10.

To configure the multiport switch block as an index vector block, set the number of data ports to 1 and data port order to zerobased contiguous. The data inputs accept real or complexvalued inputs of any type. Simulink tutorial 15 switch case using multiport switch 10. To change the number of output ports, rightclick the block and select mask parameters, then type a value in the number of choices box. Jan 22, 2017 in this video i have explained how to design switch case using multiport switch. For modeling, simulink provides a graphical user interface gui for building models as block diagrams, using clickanddrag mouse operations. This document is part of the introduction to using simulink seminar. One way to approach this would be to use a multiport switch. But today morning i am getting a ghombaro resultunexpeted result i. I recently noticed requests for a block implementing a behavior that might be called reverse multiport switch. Plc code generation generate structured text code using simulink plc coder. Zooming block diagrams simulink allows you to enlarge or shrink the view of the block diagram in the current simulink window.

Switch between two inputs simulink mathworks france. Switch between multiple variant choices at output simulink. When a block inputs both control and data signals, as switch and multiport switch do, the control signal type need not match the data signal type. It is a special configuration of the multiport switch block. Switch between two inputs simulink mathworks italia.

In this video i have explained how to design switch case using multiport switch. To toggle between the variant choices at output, doubleclick the block. The figure below illustrates how simulink performs a simulation. There are exercises in a separate document that will take you step by step through the tasks required to build and use a simulink model.

Lines between blocks connect block outputs to block inputs and represent data flow signals. You do not have to open the block dialog box to determine whether the data ports use zerobased or onebased indexing. All data inputs must be of the same data and numeric type. The control input of a multiport switch block accepts a realvalued signal of any builtin data type except boolean. The largest example that we used it for comes from the automotive domain a fuel control system, as will be described in chap. During each simulation step, simulink executes your sfunction block. Zero crossings in simulink will automatically detect exactly when the switch block changes its output, and the solver will step to the exact time that the event happens. When you increase the size of the block icon, the indices are visible on the data port labels. The manual variant source block is a toggle switch that activates one of its variant choices at the. For hdl code generation information, see multiport switch. Select a web site mathworks makers of matlab and simulink. If you set number of data ports to an integer greater than 1, the block behaves as a multiport switch.

Revision history november 1990 first printing new for simulink 1 december 1996 second printing revised for simulink 2 january 1999 third printing revised for simulink 3 release 11. This semina r is designed for people that have never used simulink. This behavior treats the input branches of a switch or multiport switch block. Blocks are the main elements you use to build models in simulink. This can be seen by examining the output in the scope. Multiport switch using simulink petra christian university. The multiport switch will select an input and pass it through to the output port based on the. Simulink patterns for logical constructs with logical blocks. Simulink multiport switch problem matlab answers matlab.

Open example a modified version of this example exists on your system. Designs are hierarchical, so that levels of details can be hidden or made explicit. Enumerated names for data port indices of the multiport. Paperpositionmode is manual, simulink positions and scales, if necessary. You do not have to open the block dialog box to determine which value maps to each data port. Simulink tutorial 15 switch case using multiport switch. The multiport switch block chooses between a number of inputs. Translation of simulink models to component citeseerx. How the block handles an outofrange control input for an input with an integer value less than intmaxint32, the input is out of range when the value does not match any data port indices. Switch, manual switch, and multiport switch signal routing library cannot select. Course introduction to matlaband simulink simulink1. Each case is associated with an output port that is attached to a switch case action subsystem block. The block output is the data input that corresponds to the value of the control input.

When block parameter data port order is set to specify indices, a value that inputs to the multiport switch block, other than the index specified for the control port, is treated the same as the last value of the specified index. Integration of simulink models with componentbased software. A simulink model is represented graphically by means of a number of interconnected blocks. When a case is selected, the associated output port sends an. The values of the indices are visible on the data port labels. As a result, an unintended data port can be selected. The output of a block is computed by an output function. Each output port is associated with a variant control. Maab control algorithm modeling guidelines using matlab. Switch between two inputs simulink mathworks deutschland. For more information about accessing and executing these demos, see chapter 2, running a model. The index vector block is a special configuration of the multiport switch block in which you specify one data input and the control input is zerobased.

You can find a few request like that on matlab answers here and here. Simulink provides numerous demos that model a wide variety of such realworld phenomena. Block types source9generatesdata sinkreceivesdata virtual9blockdealswith9logical9structure subsystem9aggregation9of9blocksreal9or9virtual custom9blockssbfunctions9cor9mbcode9based source output9yt inputut sink inputut block output9yt plot,9store,9send9to9network,9goto load9from9file,9workspace. Select zoom in from theview menu or typertoenlargetheview. In this example, the multiport switch block outputs a value of 0. The cases are evaluated top down starting with the first case. To configure a multiport switch block to work as an index vector block, set number of data ports to 1 and data port order to zerobased contiguous.

Switch between two inputs simulink mathworks espana. The first top input is called the control input, while the rest of the inputs are called data inputs. The multiport switch block determines which of several inputs to the block passes to the output. The index vector block is a multiport switch block with number of data ports set to 1. No part of this manual may be photocopied or reproduced in any. Firstclass variability modeling in matlabsimulink in. The index vector block, also in the fixedpoint blockset select library, is another implementation of the multiport switch block that has different default parameter settings. Switch output between the first input and the third input based on the value of the second input. For more details, see multiport switch configured as an index vector block. In simulink when i use multiport switch block, the hdl compatibility test gives following error. How to use matlab simulink multiport switch block duration. The manual variant sink block is a toggle switch that activates one of its variant choices at the output to pass the input the block can have two or more output ports and has one input port. Use the library browser to browse and search the block libraries. This block uses onebased indexing for contiguous ordering of three data ports.

1238 1546 758 911 1449 995 553 1153 1197 1090 951 950 1250 172 455 471 919 404 479 635 398 389 936 1312 659 379 1293 667 668 363 601 26 895 1395 150 1393 25 1281 600 1291 872 374